In autumn, the temperature difference between day and night increases, and the dust content in the air rises with the dry weather. After long-term operation of chemical fiber industrial air conditioning, problems such as component wear and dust accumulation tend to become prominent. If not properly maintained, it will reduce operational efficiency and indirectly affect the quality of textile products. This autumn maintenance tip can serve as a reference for daily upkeep.
The cleaning of the filtration system should be carried out gradually. Impurities such as cotton fluff and fibers in the textile workshop are prone to adhere to the filters. In autumn, the inspection density should be increased: the primary filter screen should be disassembled monthly and blown with compressed air, and the resistance value of the medium-efficiency filter screen should be monitored quarterly. When the value is within the range of 150-250Pa, it should be replaced in time. The dust collection device needs to be manually tapped and cleaned of dust every shift. The operating pressure should be checked weekly. If the return air is still not smooth after cleaning, it should be disassembled for thorough cleaning or replaced.
The maintenance of the temperature and humidity regulation system pays attention to details. Check the water level of the sprinkler pool every day to ensure it is 2-4cm higher than the bottom of the water deflector. At the same time, clear the debris in the water filter. Every month, the surface of the deflector plate and the water deflector plate is flushed with a high-pressure water gun. Every year, the water deflector plate is descaled, and rust removal and painting operations are carried out on the waterway pipelines to prevent rust from causing a decline in heat exchange effect.
The maintenance of the power and electronic control parts needs to be regular. Regularly add special lubricating oil to the bearings of the fan. Observe the wear and tightness of the surface of the drive belt. Deal with cracks or looseness in time if they appear. Before starting the water pump, check the flexibility of the rotating shaft. During operation, monitor the vibration and sound to prevent damage to components due to idling. The electronic control system needs to have the terminal blocks tightened regularly, and the dust on the circuit board cleaned with a dry brush to maintain the control sensitivity.
Retaining detailed maintenance records and adjusting the maintenance cycle in combination with the climate fluctuations in autumn can not only reduce equipment failures but also provide data support for subsequent maintenance, contributing to the stable operation of textile production.
Industrial air conditioning, chemical fiber industrial air conditioning, chemical fiber industry refrigeration ,textile industrial air conditioning , dust-free workshop cooling, ventilation pipeline, cooling tower, freezer and other air conditioning units and accessories.
Jiangsu Jincheng Air Conditioning Engineering Co., Ltd. is a comprehensive manufacturer of special air-conditioning equipment design, production, installation, and commissioning of clean room, electricity, tobacco, civil air defense engineering, medical clean room, clean room, electricity, tobacco, civil air defense engineering, medical clean room. Mainly produce JCZK combined air conditioning unit, cooling tower, glass steel ventilated galvanized sheet pipe, stainless steel pipe, polyurethane ventilation pipe and air conditioning accessories, Jincheng air conditioner is wide, the type, the unique model, superior performance, and user Favused.